Brand Name : Endress+Hauser

Model Number : USC70

Place of Origin : Germany

MOQ : 10PCS

Payment Terms : T/T

Supply Ability : 10000PCS / Month

Delivery Time : 5-8 workdays

Packaging Details : Carton packing

Name : USC70 Process Pressure Measurement Pressure Sensor Uart Spi Isolating Diaphragm

Media : Liquid and gaseous

Material : Ceramic

Feature : Corrosion resistance

Contact Now

Ceramic Pressure transducer USC70 Process pressure measurement pressure sensor Uart spi iisolating diaphragm
Application
Pressure sensor for use in the pressure measurement of liquid and gaseous media.
Your benefits
Dry capacitive ceramic sensor with ultrapure (99.9 %) Al2O3 ceramic
• High overload resistance
• Very good long-term stability
• High corrosion resistance
• Digital/analog signal output (SPI, UART, U)
• Measuring ranges from 0 to 0.1 bar (0 to 1.5 psi) to 0 to 40 bar (0 to 580 psi)
• Optional temperature output, switch output
Input
Measured process variable
• Gauge pressure or absolute pressure
• Temperature
Power supply
Supply voltage

Type
Value
Digital output
2.9 … 5.5 V DC
Analog output
2.9 … 5.5 V DC
Current consumption< 1.6 mA

PIN

Designation

Explanation
Application
Digital
Analog
UART SPI
1 GND Negative supply voltage X X X
2 RESET_N Reset (low active) optional optional optional
3 VDD Positive supplyvoltage V
A
X X
4 DAC Analog output optional optional optional
5 SW_OUT Switch output (open drain) optional optional optional
6 SPI_SEL Communication mode selection (UART "GND"or SPI"VDD") force to "GND" force to "VDD" force to "GND"
7 SCK SPI clock,must be connected to GND if SPI is used X
8 CS_N Chip select (low active) optional optional
9 TxD/SO_RDY Digital communication output X X
10 RxD/SI Digital communication input,must be connected to GND if not used X X force to "GND"

Output
Output signal
Type Output

Voltage output (pressure)
10 to 90%VDD (ratiometric,VDD=5.0V DC)
10 to 90 %VDDA (absolut,VDDA=2.65 VDC)

Digital output (pressure &temperature)
SPI
UART
Switch output (pressure)1) Switch (via CARMEN)
1) On request
Performance characteristics
Reference operating conditions
• As per DIN EN IEC 62828
• Ambient temperature TA = constant, in range: +23 to +27 °C (+73 to +81 °F)
• Relative humidity ϕ = constant, in range: 5 to 80 % RH.
• Ambient pressure pA = constant, in range: 860 to 1 060 mbar (12.47 to 15.37 psi)
• Position of measuring cell = constant, in range: process isolating diaphragm pointing downwards
(see also the "Influence of installation position" section ä 11)
• Analog output supply voltage: 4.9 to 5.1 V DC
• Digital output supply voltage: 2.9 to 5.5 V DC
• Reference installation of Endress+Hauser (Components and Mounting instructions SD02509P)
Reference accuracy
The reference accuracy includes the non-linearity [DIN EN 61298-2 3.9], the non-repeatability
[DIN EN 61298-2 3.10] and the pressure hysteresis [DIN EN 61298-2 3.11] in accordance with the
limit point method as per [DIN EN 61298-2].
Long-term stability
≤ 0,1 %/year related to the upper range limit (URL).
Process temperature range
–40 to +125 °C (–40 to +257 °F)
Compensated range –20 to +80 °C (–4 to 176 °F)
Ambient temperature range
–40 to +125 °C (–40 to +257 °F)
Compensated range –20 to +80 °C (–4 to 176 °F)
Storage temperature range
–40 to +125 °C (–40 to +257 °F)
Electromagnetic compatibility (EMC)
No specifications (open system)
Overvoltage protection
6 V DC (maximum voltage for CARMEN ASIC)
Calibration; unit
Designation
Nominal range;mbar
Nominal range;bar
Nominal range;psi
Nominal range;Pa
Nominal range;kPa
Nominal range;MPa
Nominal range;mmHO
Nominal range;mHO
Nominal range;inHO
Nominal range;ftHO
Nominal range;mmHg


Product Tags:

Uart Measurement Pressure Sensor

      

Spi Measurement Pressure Sensor

      

Isolating Diaphragm Pressure Sensor

      
Quality USC70 Process Pressure Measurement Pressure Sensor Uart Spi Isolating Diaphragm wholesale

USC70 Process Pressure Measurement Pressure Sensor Uart Spi Isolating Diaphragm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SENSE Instruments Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)